COMPACT - II
GPD: 150 - 800
- Compact design requires minimal installation space
- Designed for municipal/tap water source
- Quality components utilized for system construction
- Designed for optimum water recovery
- Adjustable waste and recycle flow controls
- Quick and easy system installation
- Available for pressure or open tank applications
- 12 Month (One Year) Factory warranty
- Output Production: 150 gpd to 800 gpd
|
  |
STANDARD FEATURES
- Thin film composite membrane
- PVC membrane housing
- Powder-coated steel frame
- Inlet and outlet pre-filter gauges
- Liquid-filled system pressure gauge
- Pressurized tank pressure gauge
- Adjstbl. waste/recycle valves
- High-pressure nylon tubing
- High-pressure brass comp. fittings
- Storage tank pressure switch
- Low-pressure switch
- Feed water inlet solenoid valve
- 1/2 hp 50/60 hz motor (150-450gpd)
- 3/4 hp 50/60 hz motor (800gpd)
- Rotary vane pump
- 20” 5 micron sediment pre-filter
- 20” carbon block pre-filter
- Salt rejection 95 - 99%
|
OPTIONS:
- Float switch for atmospheric storage tank
- Product and waste flow meters
- Stainless steel pump
- Automatic hourly flush
- Stainless steel membrane housing
- Manual flush
- Additional pre-treatment, see below:
- Stainless steel needle valves
- 220 volt motor
The pre-filtration on the COMPACT is sufficient for the 150 and 250 gpd models. It is advisable that additional pre-treatment be installed in front of the COMPACT for the 450 and 800 gpd models. Higher volumes of water passing through the COMPACT can shorten filter life.
|
FEED WATER PARAMETERS:
STemperature 85o F maximum SPressure 40 - 80 psi maximum STDS 2000 ppm maximum. If higher, consult factory SIron tolerance 0.5 ppm maximum SHydrogen sulfide must be removed S Silica tolerance can not be higher than 125 ppm in the concentrate stream. Antiscalant should be considered for any levels over 75 ppm. STurbidity should be removed SHardness over 10gpg should be softened.
OPERATING PARAMETERS:
SOperating pressure 200 psi maximum SWater recovery is adjustable and suggested to be set at 33%. Water recovery should not exceed 50% SpH range 3 - 11 SFlow rates are determined by the membrane mfgr’s. testing criteria of 1500 ppm Nacl solution, 77oF water temperature, 225 psi at 10-15% recovery. Actual flow rates may vary depending on the pre-treatment used, water conditions, system size, membrane array and applied pressure.
|
MODEL |
GPD
(minimum) |
MEMBRANE |
PIPING
inlet waste prod |
DIMENSIONS |
Order |
Price |
COM-II 150 |
150 - 200 |
2.5” x 14” 1ea. |
3/8” 3/8” 3/8” |
14” x 16” x 30”H 85 lbs. |
|
$1355.00 |
COM-II 250 |
250 - 400 |
2.5” x 21” 1ea. |
3/8” 3/8” 3/8” |
14” x 16” x 30”H 88 lbs. |
|
$1845.00 |
COM-II 450 |
450 - 600 |
4” x 14” 1ea. |
3/8” 3/8” 3/8” |
14” x 16” x 30”H 92 lbs. |
|
$1915.00 |
COM-II 800 |
800 - 900 |
4” x 21” 1ea. |
1/2” 3/8” 3/8” |
14” x 16” x 30”H 95 lbs. |
|
$2050.00 |
|