Filtration Station
FILTRATION STATION
GPD: 1,500 - 7,200
Skid #1 Contains:
Pre-treated equipment which includes water softener and carbon filtration
Skid #2 Contains:
- System control package
- Reverse Osmosis System
- Quality components utilized for system construction
- High pressure pump/motor
- Stainless steel depressurization pump with 10 gallon pressure tank
- Parallel carbon block post-filters
- Ultra violet water sterilization (Ozone Optional)
- Output Production: 1,500 gpd to 7,200 gpd
- The filtration Station is pre-plumbed and pre-wired to minimize installation time. 600 Gallons of product water storage, tank adapters, and fittings are also included.
|
 |
STANDARD FEATURES
- 1.5 cu.ft. twin tank water softener w/auto backwash
- 1.5 cu.ft. carbon filter w/auto backwash
- 5 micron pre-filter
- Stainless steel multi-stage pump
- Thin Film Composite membrane
- PVC membrane housing
- Adjstbl. waste/recycle needle valves
- Product/waste flow meters
- 1HP s. s. repressurization pump w/10 gallon pressure tank
- Two 20” GAC carbon block post-filters
- Pre and post-filter gauges
- System PSI gauge
- Stainless steel 24gpm ultraviolet water sterilizer
- Stainless steel pre-treatment jackets
- Marine-grade back panels
- Powder-coated steel frame w/casters
- Two 300 gallon polyethylene storage tanks w/adaptors
|
STANDARD ELECTRICAL CONTROLS
- Off/On switch
- Automatic hourly flush
- Fused power
- Motor contactors
- Time delay
- TDS monitor
- UV light switch
- System control switch
- Repress. switch
- Low pressure switch
- Hour meter
- Pre-treat lock-out
- Off delay
- Low press. off delay
- Dual level controller (R.O.)
- Dual level controller (repressurization)
STATUS LAMPS:: power, running, flushing, low pressure, tank full, pre-treat lock-out, low level
POWER REQUIRED:
220v/ 60hz, 30 amp, 1Ø or 220v / 60hz, 15 amp, 3Ø |
FEED WATER PARAMETERS:
STemperature 85o F maximum SPressure 40 - 80 psi maximum STDS 2000 ppm maximum. If higher, consult factory SIron tolerance 0.5 ppm maximum SHydrogen sulfide must be removed S Silica tolerance can not be higher than 125 ppm in the concentrate stream. Antiscalant should be considered for any levels over 75 ppm. STurbidity should be removed SHardness must be removed.
OPERATING PARAMETERS:
SOperating pressure 200 psi maximum SWater recovery up to 60% and is field adjusted by customer. It is not recommended that the recovery be set higher than 50%. Only under certain conditions can the recovery be set higher. SpH range 3 - 11 SFlow rates are determined by the membrane mfgr’s. testing criteriea of 1500 ppm Nacl solution, 77oF water temperature, 225 psi at 10-15% recovery. Actual flow rates may vary depending on the pre-treatment used, water conditions, system size, membrane array and applied pressure. |
OPTIONS:
- Ozone generator (bubbler type)
- Ozone generator (corona discharge)
- Feed water pump
- Back washing media pre-filter
- Gallon meter
- Stainless steel needle valves
- Stainless steel membrane housing
- 50 hz electrical
- Shipping crate
|
MODEL |
GPD
(minimum) |
MEMBRANE
size and qty |
MOTOR |
DIMENSIONS |
Order |
Price |
FS-1 |
1,500 - 2,000 |
4” x 40” 1 ea. |
1 HP |
110”L x 31” x 66”H 1,800 lbs. |
|
$12,195.00 |
FS-2 |
3,000 - 4,000 |
4” x 40” 2 ea. |
2 HP |
110”L x 31” x 66”H 1,800 lbs. |
|
$12,695.00 |
FS-3 |
4,500 - 6,000 |
4” x 40” 3 ea. |
2 HP |
110”L x 31” x 66”H 1,800 lbs. |
|
$13,595.00 |
FS-4 |
6,000 - 8,000 |
4” x 40” 4 ea. |
3 HP |
110”L x 31” x 66”H 1,800 lbs. |
|
$14,195.00 |
|
|